Heat Shrinkable Joints & Terminations
Cable Terminations - GXO/E - 1524 - Series Heat
Shrinkable Terminations Suitable for 3 Core XLPE/EPR Insulated Cables For 24kV
Descriptions : GXO / E - 1524 - Series Class I termination kits are
Heat Shrinkable termination kits designed for 3 Core extruded dielectric, shielded.
armoured & unarmoured 24 KV rated voltage (8.7KV/15KV, 11kV/11kV, 12.7/22kV,
Umax=24KV).
- Cable Components
- 3.
- Semi Conducting Screen
- Kit Components
-
- 6.
- Terminal Sleeve
- 3 Nos.
- 7.
- Non-Tracking Weather Resistant Tubing
- 3 Nos.
- 8.
- Stress Control Tubing
- 3 Nos.
- 10.
- Non-Tracking Cable Break Out
- 1 No.
- 11.
- Tinned Copper Earth Braid
- 1 No.
- 14.
- Worm Drive Clips
- 2 Nos.
- 15.
- Mastic Sealing Tape
- 1 Roll.
- 17.
- Lug Sealing Tape
- 3 Nos.
- 18.
- Stress Control Mastic
- 3 Nos.
- Installation aids & Accessories (Part of
std. Kits)
-
- 1
- Armour Earthing Arrangement (Tinned
Copper Braid + Back Up Ring + Jubilee Clamp)
- 1 Set.
- 2
- Metal shield Earthing arrangement (Small
Copper Braid + Solder + Flux)
- 1 Set.
- 5
- Nylon String for Cutting XLPE Insulation
- 1 No.
- 6
- Aloxite Emery Tape
- 3 Nos.
- 8
- Installation Instruction Manual
- 1 No.
Electrical Performance (12 kV Rated Accessories)
- Tests
- Requirement Test Value
- GXO/E-112-Series
- AC Withstand 1 Minute
- 35KV
- Pass
- DC Withstand 30 Minute
- 48 KV
- Pass
- Discharge Extintion Voltage (< 5Pc.)
- 12.7 KV
- >12.7kV
- Impulse Withstand (Crest kV)
- 75 kV
- >75 kV
- Continuous Current Rating
- As Per Cable
- As Per Cable
Accessories and optional items
- Standard Tail Length is 600mm for outdoor and 450mm for indoor terminations. Special
tail lengths available on request.
- Solderless and special purpose earthing kits also available on request.
- Polymeric Insulators and T Brackets for installation of terminations on single pole
are available on request.
- Temperature sensitive paint changes colour when heat shrinking process is complete.
Note
- All kits are supplied with full kit contents for making a termination.
- All Indoor Kits are supplied without rain sheds.
Ordering Informations
- Cable size (sq. mm)
- Outdoor Kit Code
- Indoor Kit Code